CALIBRATOR, CURRENT LOOP
Aperçu
description
Description rapide
Sku: VC05
Informations Supplémentaires
mA sourcing, simulation and measurement
0-28 VDC measurement to check loop voltage
0.02% accuracy and 0.001% of span display
Simulate mA and % of span display
Selectable step or ramp outputs
24V loop power supply
Includes test leads, allligator clips, protective holster, soft carrying case and batteries
Specifications:
Measurement Function
Voltage Range: -0.200 to 28.000V
Resolution: 1mV
Accuracy: ±0.02% rdg. ±2mV
Current Range: -1.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±4µA
Loop Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±4µA
Output Function
Current Range: 0.000 to 22.000mA
Resolution: 0.001mA
Accuracy: ±0.05% ±4µA
Loop Power Range: 24V
Accuracy: ±10%
Power Supply: Single 9V battery
Battery Life: Approx. 12 hours
Dimensions: 200 x 100 x 40mm
Weight: 550g
Soyez le premier à commenter ce produit
544,60 $CA
En stock
Qté :
Ajouter au panier
View Product Details